H0530 Temperature transmitter and regulator with Ethernet interface

H0530 Temperature transmitter and regulator with Ethernet interface

code: H0530
Ambient temperature transmitter with two relay outputs.

Built-in temperature sensor.

Temperature transmitter is equipped with three two-state inputs for detection of  two-state signals - e.g. power presence, water, smoke, airflow, glass break detection, door contact.

Included in delivery: 

  • Traceable calibration certificate
  • Quick start manual
  • Free program TSensor for configuring of the transmitter is ready to Download
  • Free program SensorReader for logging values from one transmitter to a PC disk file is ready to Download

 

   
Features Technical Data Download Optional accessories We recommend

Features

Temperature transmitter is equipped with three binary inputs for detection of two-state events - e.g. water, smoke, glass break detection, door contact.

Degrees Celsius and Fahrenheit are user selectable.

Parameters are easy adjustable from transmitter keyboard or from the computer.

Transmitter is equipped with two relay outputs for alarm indication or control of external devices. For each relay setting of delay, hysteresis, audible alarm is enabled.

 

Easy creation of online data acquisition system from Ethernet sensors by using new low cost database software Comet

DBS Sensor Monitor

Online Ethernet Monitoring System

- see also Optional Accessories.

MODES OF COMMUNICATION
Modbus TCP: Modbus TCP protocol enables to read measured values, set alarm limits, adjust the probe.
Telnet: Port 9999 enables to set alarm limits (lower, upper limits, hysteresis for measured values and time delay), e-mail addresses, SNMP addresses, probe description, refresh of www pages (10s to 65535s), set storing interval to history (10s to 65535s), enable each communication channel. Capacity of the history memory is 100 sets of temperature. Password protection of this port is enabled. Automatic IP address assignment from DHCP server is also enabled.
WWW pages: User selectable design of www pages enabling to display curve of measurement history. User can design the look of www pages and temperature values history.
SNMP: It is possible to read actual values and alarm limits. In case of alarm creation warning message (trap) is sent to addresses defined by the user (maximum three addresses).
SOAP: Online transmitter enables to send actual measured data in the format of SOAP message to selected web server in preset interval 10-65535 s.

Online transmitter enables to monitor measured values. In case of exceeding of adjusted limits warning message can be sent to specified addresses. 

There are the following options of alarm indication:

ALARM INDICATION OPTIONS
E-mail: In case of alarm creation warning e-mail message is sent to addresses defined by the user (maximum three addresses) or via e-mail to SMS message. Basic SMTP autentization is supported.
SNMP: In case of exceeding of adjusted temperature value limits alarm is activated and warning trap is sent to user specified IP addresses (maximum 3 addresses).
WWW pages: In case of exceeding of adjusted temperature value limits active alarm is displayed on www page.
syslog: Online transmitter enables to send text messages to selected syslog server after different events appear. E.g. after transmitter restart, alarm activation, communication error with SNTP, after firmware change, after alarm termination, after communication error with SOAP server.

Synchronizing of time and record to www table and measured values history is enabled by SNTP via Internet.

 

For acquiring values from several transmitters, also third party software is possible to use. Tested functionality is with programs:

LabVIEW from National Instruments, by means of the free Modbus Library for LabVIEW.

TIRS.NET - transmitters are also directly supported by program TIRS.NET from Coral s.r.o. company. Please download demo enabling full work with transmitters.

Tested functionality is also with program ControlWeb

Technical Data

Technical parameters Value
Output Ethernet
Measured Value Temperature
Construction Type Ambient Air
Design Industrial
Temperature Measuring Range -30 to +80°C
Relay Output Yes
Two-State Input Yes
Lcd Display Yes
Accuracy of temperature output ±0.4°C
Resolution 0.1°C
Measuring interval 2s
Available temperature units degrees Celsius, degrees Fahrenheit
Temperature operating range -30 to +80°C
IP protection IP40
Number of relay outputs 2
Maximum switching voltage, current and power of the relay output 50V, 2A, 60VA
Number of binary inputs 3
Signal for binary inputs dry contact, open collector or two-state voltage signal.
Inputs are not galvanically isolated.
Minimum pulse length at binary input 500ms
Low voltage level at binary input 0 to +0.5V
High voltage level at binary input +3.0 to +30V
Audible alarm built-in beeper - switchable
LAN connection RJ-45 connector, 10Base-T or 100Base-TX
Communication protocols WWW, ModbusTCP, SNMPv1, SOAP
Alarm protocols E-mail (SMTP authentication is supported), SNMP Trap, Syslog
Configuration T-Sensor, Telnet, keyboard
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Power 9 to 30Vdc, maximum consumption 1W
Power connector co-axial, diameter 5.5 x 2.1mm
Dimensions 136 x 191 x 45mm (W x H x D), stem length 53mm
Weight approximately 340g
Warranty 2 years

  size
doc Instruction Manual 2.1 MB
doc Quick Start Manual 770 kB
doc Datasheet 1.5 MB
doc Declaration of Conformity 30 kB
doc MIB tables 250 kB

Program TSensor - free configuration program for transmitters and transducers, Code: TSensor more »
doc TSensor - free configuration program version 3.0.5.0 2.6 MB
doc TSensor - revision history 8 kB

Program SensorReader - free program for data read and store from one sensor, Code: SensorRead more »
doc SensorReader - free program for data recording from one sensor, version 2.0.1.0 1.3 MB

DBS Sensor Monitor - database program for data acquisition from Ethernet sensors P8xxx, Tx5xx, Hx5xx, Code: DBS more »
doc DBS Database Sensor Monitor version 2.3.0.1_II 55.2 MB

DBV Database Viewer for database programs DBL, DBM, DBS, Code: DBV more »
doc DBV Database Viewer 2.3.0.1 22.8 MB

Optional accessories

DBS Sensor Monitor - database program for data acquisition from Ethernet sensors P8xxx, Tx5xx, Hx5xx
code: DBS
Online monitoring system with sensors connected to Ethernet
DBV Database Viewer for database programs DBL, DBM, DBS
code: DBV
Low cost browser DBV Database Viewer enables several clients to view database from different places on network/internet.
H3060 temperature and humidity regulator with 230Vac/8A relays
code: H3060
Humidistat, thermostat with two relay outputs. Outdoor, indoor use.
H4531 Temperature transmitter with alarms with Ethernet interface
code: H4531
Temperature transmitter for Pt1000 sensors with two relay outputs.
H4531R temperature transmitter - rack mount monitor
code: H4531R
Temperature transmitter with two relay outputs.
Web sensor T0510 - remote thermometer with Ethernet interface
code: T0510