COMET SYSTEM, s.r.o.
1.maje 1220
756 61  Roznov pod Radhostem
CZECH REPUBLIC
Tel.: +420 571 653 990

E-mail: info@cometsystem.cz


 

Transmitters
And Regulators
Data
Loggers
Monitoring
Systems
Temperature
Recorder with Printer
Portable
Instruments
Temperature
Probes
Software

T0210 Temperature and humidity outdoor, indoor probe with 0-10V output

T0210 Temperature and humidity outdoor, indoor probe with 0-10V output

code: T0210
Ambient temperature, relative humidity transmitter. Outdoor, indoor use.

Built-in relative humidity, temperature sensors. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

Included in delivery:

  • Traceable calibration certificate
  • Quick start manual
  • Free program TSensor for configuring of the transmitter is ready to Download

   
Features Technical Data Download Optional accessories We recommend

Features

Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals and sensors in a filter with stainless steel mesh. Transmitters are available with two 0-10V outputs. Configuration of outputs and output range are user adjustable. Large dual line LCD for simultaneous display of T+RH or other humidity interpretation is an advantage. Display is possible to switch off. Computerized design ensures temperature compensation of the humidity sensor and fail indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment. 

 

APPLICATIONS - measuring and control of air humidity at:

  • building HVAC management
  • building HVAC automation
  • warehouses
  • glasshouses
  • manufacturers
  • museums, archives, galleries
  • air-conditioned rooms
  • weather stations 

Transmitters are approved and homologated by
RENAULT and by PSA (PEUGEOT / CITROEN) car manufacturers.

Outputs are set to maximum range from the manufacturer (-30 to +80°C, 0 to 100%RH).
To set other range by the user buying of SP003 cable is necessary - see Optional accessory.
Free configuration program TSensor for transmitter adjustment is ready to download anytime.

If different adjustment of outputs is required, please specify required output values (RH, T, Tdp, ..) and required ranges in the order. Adjustment is free of charge.

Any measured value - temperature, relative humidity, dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy can be assigned to each output of dual output transmitters. Also identical value can be assigned to both outputs.

Ordering example: Humidity transmitter T0210, output 1: RH 10 to 90%, output 2: temperature 0 to 35°C

Application wiring of the humidity transmitter

Typical application wiring

Maximum loading current of each voltage output is 0,5 mA.

Technical Data

Technical parameters Value
Output 0-10V
Measured Value Relative Humidity + Temperature
Construction Type Ambient Air
Design Industrial
Temperature Measuring Range -30 to +80°C
Relay Output No
Two-State Input No
Lcd Display Yes
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C
Available temperature units degrees Celsius, Fahrenheit
Accuracy and range of dew point temperature output - for more details see graphs ±1.5°C at ambient temperature T<25°C and RH>30%
range -60 to +80 °C
Accuracy and range of absolute humidity output ±1.5g/m3 at ambient temperature T < 25°C
range 0 to 400 g/m3
Accuracy and range of specific humidity output ±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg
Accuracy and range of mixing ratio output ±2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg
Accuracy and range of specific enthalpy output ±3kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg
Temperature operating range -30 to +80°C
Temperature operating range of LCD display readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Range of humidity sensor temperature compensation all temperature range
Voltage outputs 0-10V, outputs are not galvanic isolated - have common ground
Configuration of outputs and output range user adjustable from the PC
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
Protection of the case with electronics IP65 electronics, IP40 sensors
Power 15-30Vdc, maximum consumption 20mA
Dimensions 88.5 x 170 x 39.5 mm (W x H x D), stem length 75 mm
Weight approximately 150g
Warranty 2 years

Optional accessories

T0213 Temperature and humidity duct probe with 0-10V output T0213 Temperature and humidity duct probe with 0-10V output
code: T0213
Humidity, temperature transmitter. Outdoor, indoor use. Duct mount.
T0211 Temperature and humidity probe with 1m cable and 0-10V output T0211 Temperature and humidity probe with 1m cable and 0-10V output
code: T0211
Humidity, temperature transmitter. Outdoor, indoor use.