Thermo-hygrometer + external probe
|
|
code: R3121 Thermometer hygrometer is designed for record of temperature. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter. Included in delivery:
For communication with the PC must be from Optional accessories ordered USB adapter, LAN adapter or COM adapter or start/stop magnet if is needed to control logging the other way than directly from computer. |
Features
Main applications of data logger:
- Food and beverage industry (HACCP)
- Pharmaceutical industry
- Horticulture and cultivation of plants
- HVAC (heating, ventilation, air conditioning, cooling)
- Building and energy management
- Research and development
- Laboratories (GLP)
- Warehouses
- Technological processes
- Museums, archives, galleries
Advantages of data logger:
- included traceable calibration certificate from the manufacturer - Comet
- fast data transfer to the PC (full memory for approximately 30s)
- variability of connection to the computer - USB, RS232, Ethernet, GSM modem
- permanent connection to the PC enabled, data is possible to download even during logging
- large data memory 32000 values
- large dual line display with special symbols, switchable
- optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
- dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display
- two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared from the PC)
- robust watertight case
- easy installation, locking enabled
- low power consumption from battery, battery life up to 6 years
- indication of remaining battery life, easy replacement of the battery
- logging start/stop is enabled in several ways: at certain time and date programmed from computer, by delivered magnet
- also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
- each data logger is possible to describe with text of maximum 32 characters
- each channel is possible to describe with text of maximum 16 characters
- password protection is enabled to prevent unauthorized manipulation with logger


Figure: Relative humidity operating range

Figure: Accuracy of dew-point measurement
Technical Data
| Technical parameters | Value |
|---|---|
| Measured Value | Relative Humidity + Temperature |
| Construction Type | With T+RH Probe On Cable |
| Temperature Measuring Range | -30 to +105°C |
| Two-State Input | No |
| Lcd Display | No |
| Built-In Printer | No |
| Operating temperature range | -30 to +80°C |
| Measuring range of the probe | temperature -30 to +105°C, humidity 0 to 100%RH |
| Accuracy of temperature measurement | ±0.4°C from –30 to +80°C, ± 0.5 °C over +80°C |
| Accuracy of humidity measurement | ±2.5% RH from 5 to 95% at 23°C |
| Accuracy of dew point measurement - see details in graph | 1.5 °C at ambient T < 25°C and RH>30% range -60 to +70 °C |
| Resolution of the reading | 0.1°C, 0.1%RH |
| Real time clock | year, leap year, month, day, hour, minute, second |
| Data logging interval | adjustable from 10s to 24h (1minute to 24h in low-power mode) |
| Alarm refresh | each 10 s (each 1 minute in low-power mode) |
| Total memory capacity | 32000 temperature, humidity values in noncyclic logging mode |
| Data logging modes | noncyclic - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new |
| Dimensions without probe | 93x64x27mm |
| Power | Lithium battery 3,6V, size AA |
| Typical battery life in low-power mode (1 minute sampling) | 7 years |
| Typical battery life in fast mode (10 second sampling) | 3 years |
| Battery life in continuous on-line mode with interval 1 minute | reduced to 70% of the above lives in fast mode |
| Battery life in continuous on-line mode with interval 10 second | 1 year |
| IP protection | IP67 - protected against influence of temporary immersion into water, RH+T sensors are covered with a stainless steel mesh with IP40 protection. Filtering ability 0,025mm |
| Weight including battery | 105g |
| Warranty | 2 years |
| size | |
|---|---|
Instruction Manual |
450 kB |
Datasheet |
1.1 MB |
Declaration of Conformity |
60 kB |
| Program for Data Loggers Sxxxx, Rxxxx, Gxxxx, Dxxxx, Code: SWR004 | more » |
|---|---|
SWR004 Program for Data Loggers version 3.0.0.15 |
13.6 MB |
| DBL Logger Program - database software for Sxxxx, Rxxxx, Gxxxx data loggers, Code: DBL | more » |
|---|---|
DBL Logger Program version 3.0.0.17.II |
61.8 MB |
| DBV Database Viewer for database programs DBL, DBM, DBS, Code: DBV | more » |
|---|---|
DBV Database Viewer 2.3.0.1 |
22.8 MB |
Optional accessories
|
KIT - GSM/GPRS modem LP040 with accessories for Sxxxx, Rxxxx loggers
code: KIT-GSM-L
|
COM adapter with protection IP65
code: LP012
|
GSM/GPRS MODEM for data loggers of Sxxxx, Rxxxx, Gxxxx families
code: LP040
|
|
antenna for GSM modem FASTRACK
code: MP009/1
|
AC/DC adapter 230Vac to 24Vdc/1A, switch-mode
code: A1940
|
Backup power supply for GSM modem LP040
code: BP12
|
|
Communication cable for GSM modem
code: QMS2901
|
Transducer USB/RS232 complete
code: MP006
|
Self Adhesive Dual Lock
code: MD036
|
|
Wall holder for GPRS modem
code: MP036
|
DIN Rail 35mm holder for GPRS modem
code: MP037
|
One time fee for using M2M server - applied for each data logger with modem
code: SLU302
|
|
Start/stop magnet
code: LP004
|
USB adapter
code: LP003
|
COM adapter with protection IP65
code: LP012
|
|
LAN adapter with 0.5 meter cable
code: LP005
|
LAN adapter with 5 meter cable
code: LP005-5
|
Lithium battery 3,6V/AA
code: A4203
|
|
plastic sensor protection with stainless filter (black)
code: F5200B
|
Multi-plate radiation shield
code: F8000
|
wall holder for datalogger
code: F9000
|
|
Self Adhesive Dual Lock
code: MD036
|
PP4 Flat circular flange
code: PP4
|
PP90 Right-angled stainless steel flange
code: PP90
|
|
Vessel for adjustment and calibration of humidity
code: MD046
|
Humidity Standard 10%RH, set 5pcs
code: HM023
|
Humidity Standard 80%RH, set 5pcs
code: HM024
|
|
DBL Logger Program - database software for Sxxxx, Rxxxx, Gxxxx data loggers
code: DBL
Database program package. |
|
DBV Database Viewer for database programs DBL, DBM, DBS
code: DBV
Low cost browser DBV Database Viewer enables several clients to view database from different places on network/internet. |
|
Program for Data Loggers Sxxxx, Rxxxx, Gxxxx, Dxxxx
code: SWR004
Program for Windows for data loggers of Rxxxx, Sxxxx, Gxxxx, Dxxxx, ZV families. |
|
LAN adapter with 0.5 meter cable
code: LP005
LAN adapter - external converter for Sxxxx, Rxxxx loggers communication with the PC via Ethernet, including ac/dc adapter 100 to 240Vac/5Vdc.
Length of the cable 0.5 m.
Protection IP65.
Exceeding of adjusted limits is alarmed by sending e-mail message or SNMP trap. |
|
Thermo-hygrometer with external probe
code: S3121
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter. |
|
Thermo-hygrometer
code: R3120
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter. |


COMET SYSTEM, s.r.o.
Instruction Manual
SWR004 Program for Data Loggers version 3.0.0.15
DBL Logger Program version 3.0.0.17.II

































