COMET SYSTEM, s.r.o.
1.maje 1220
756 61  Roznov pod Radhostem
CZECH REPUBLIC
Tel.: +420 571 653 990
Fax: +420 571 653 993
E-mail: info@cometsystem.cz


 

Transmitters
And Regulators
Data
Loggers
Monitoring
Systems
Temperature
Recorder with Printer
Portable
Instruments
Temperature
Probes
Software

C0321 Thermocouple thermometer dual channel

C0321 Thermocouple thermometer dual channel

code: C0321
High accuracy thermometer for thermocouple J, K, S. Audio and optical alarm of measured temperature. Minimum/maximum memory. memory of minimum and maximum temperature included traceable calibration certificate automatic compensation of thermocouple cold junction temperature.

Included in delivery:

Instrument including the battery

  • Traceable calibration certificate
  • Instruction manual
  • Plastic transport case
  • Connector for external ac/dc adapter
  • Self Adhesive DualLock
   
Technical Data Download Optional accessories We recommend

Features

Technical Data

Technical parameters Value
Measured Value Temperature From J,K,S Thermocouple
Construction Type For Two External Temperature Probes
Temperature Measuring Range -200 to +1700°C
Data Logging Function No
Operating temperature range -10 to +60°C
Connector for probe connection subminiature connector for thermocouples
Accuracy without probes - thermocouples K (NiCr-Ni) ±(0.4°C + 0.1% from reading) from -200 to +1300°C
Accuracy without probes - thermocouples J (Fe-Co) ±(0.4°C + 0.1% from reading) from -200 to +750°C
Accuracy without probes - thermocouples S (Pt10%Rh-Pt) ±(0.85°C + 0.1% from reading) from -50 to +1700°C
Resolution J,K thermocouples: 0.1°C from -99.9 to +999.9°C, otherwise 1°C
S thermocouples: 0.4°C from -50.0 to +999.9°C, otherwise 1°C
Power battery 9V
Battery life 2 months typically
Dimensions 141 x 71 x 27 mm
IP protection IP20
Weight including battery approximately 150 g
Warranty 2 years

Optional accessories

CP500 thermocouple K surface probe
code: CP500
CZ550 thermocouple K surface probe
code: CZ550
CZ900 thermocouple K needle probe
code: CZ900
GD1250 thermocouple "K" wire probe 1m
code: GD1250-1
GD1250 thermocouple "K" wire probe 2m
code: GD1250-2
GD1250 thermocouple "K" wire probe 3m
code: GD1250-3
GD1250 thermocouple "K" wire probe 4m
code: GD1250-4
GD260 thermocouple "K" wire probe 1m
code: GD260-1
GD260 thermocouple "K" wire probe 2m
code: GD260-2
GD260 thermocouple "K" wire probe 3m
code: GD260-3
GD260 thermocouple "K" wire probe 4m
code: GD260-4
GD700 thermocouple "K" wire probe 1m
code: GD700-1
GD700 thermocouple "K" wire probe 2m
code: GD700-2
GD700 thermocouple "K" wire probe 3m
code: GD700-3
GD700 thermocouple "K" wire probe 4m
code: GD700-4
GT1150 thermocouple "K" insertion probe
code: GT1150
Extension cable thermocouple K,1meter
code: SNP03
Extension cable thermocouple K,2meters
code: SNP06
Extension cable thermocouple K,3meters
code: SNP07
Extension cable thermocouple K,4meters
code: SNP08
Extension cable thermocouple K,5meters
code: SNP09
Extension cable thermocouple K,6meters
code: SNP10
Extension cable thermocouple K,7meters
code: SNP11
Extension cable thermocouple K,8meters
code: SNP12
Extension cable thermocouple K,9meters
code: SNP13
Extension cable thermocouple K,10meters
code: SNP14
Extension cable thermocouple K,11meters
code: SNP15
Extension cable thermocouple K,12meters
code: SNP16
Extension cable thermocouple K,13meters
code: SNP17
Extension cable thermocouple K,14meters
code: SNP18
Extension cable thermocouple K,15meters
code: SNP19
D0321 Thermocouple thermometer dual channel
code: D0321
Thermometer is designed for direct measurement and datalogging of temperature into the internal non-volatile memory. Free PC program enables to transfer recorded data via RS232 serial link to the personal computer for consequent evaluation. Instrument is connected to the PC through included communication cable only for data trasfer from the memory. During connection with the PC no measurement and record is enabled.
D0221 Dual channel thermometer Ni1000/Pt1000
code: D0221
Thermometer is designed for direct measurement and datalogging of temperature into the internal non-volatile memory. Free PC program enables to transfer recorded data via RS232 serial link to the personal computer for consequent evaluation. Instrument is connected to the PC through included communication cable only for data trasfer from the memory. During connection with the PC no measurement and record is enabled.