dual chann. 0-20mA current datalogger with display
|
|
code: S6021 Data logger is designed for record of current. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter. Included in delivery:
For communication with the PC must be from Optional accessories ordered USB adapter, LAN adapter or COM adapter or start/stop magnet if is needed to control logging the other way than directly from computer. |
Features
Main applications of data logger:
- Distant places with no electric power
- Long term field measurement
- Research and development
- Laboratories
- Technological processes
Advantages of data logger:
- included traceable calibration certificate from the manufacturer - Comet
- fast data transfer to the PC (full memory for approximately 30s)
- variability of connection to the computer - USB, RS232, Ethernet, GSM modem
- permanent connection to the PC enabled, data is possible to download even during logging
- large data memory 32000 values
- large dual line display with special symbols, switchable
- optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
- dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display
- two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared)
- robust watertight case
- easy installation, locking enabled
- low power consumption from battery, battery life up to 6 years
- indication of remaining battery life, easy replacement of the battery
- logging start/stop is enabled: at certain time and date programmed from computer, by external binary signal or by delivered magnet
- also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
- input signal is recalculated and displayed in real measured physical units by means of the PC software
- each logger is possible to describe with text of maximum 32 characters
- each channel is possible to describe with text of maximum 16 characters
- password protection is enabled to prevent unauthorized manipulation with logger

GSM COMMUNICATION - read more
Technical Data
| Technical parameters | Value |
|---|---|
| Measured Value | Current |
| Operating temperature range | -30 to +70°C |
| Measurement accuracy | ±0.2% FS |
| Resolution of current input | 7900 levels |
| Signal character at binary input | from potential-less contact or two-state voltage signal |
| Minimum pulse duration at binary input | 500 ms (shorter pulses may not be recorded) |
| Maximum frequency at binary input | 0.5 Hz (i.e. maximum 5 pulses for 10 s) |
| Power current through contact at binary input | 3 uA (contact closed) |
| Voltage accross open contact at binary input | maximum 3.6 V |
| Low voltage level at binary input | 0 to +0.2 V (maximum current from the input 3 uA) |
| High voltage level at binary input | +3.0 to +30 V (maximum current to the input 100 nA) |
| Built-in connector for input signals | D-Sub 9 pins, male |
| Real time clock | year, leap year, month, day, hour, minute, second |
| Data logging interval | adjustable from 10s to 24h |
| Display and alarm refresh | each 10s |
| Total memory capacity | 32 504 records in noncyclic logging mode, 28 896 records in cyclic logging mode |
| Data logging modes | noncyclic - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new |
| Power | Lithium battery 3,6V, size AA |
| Typical battery life in low-power mode (1 minute sampling) | 6 years |
| Battery life in continuous on-line mode with interval 1 minute | 4 years |
| Battery life in continuous on-line mode with interval 10 second | 1 year |
| IP protection | IP67 - protected against influence of temporary immersion into water |
| Dimensions without connectors | 93x64x29mm |
| Weight including battery | approximately 130g |
| Warranty | 2 years |
| size | |
|---|---|
Instruction Manual |
550 kB |
Datasheet |
1.1 MB |
Declaration of Conformity |
60 kB |
| Program for Data Loggers Sxxxx, Rxxxx, Gxxxx, Dxxxx, Code: SWR004 | more » |
|---|---|
SWR004 Program for Data Loggers version 3.0.0.15 |
13.6 MB |
| DBL Logger Program - database software for Sxxxx, Rxxxx, Gxxxx data loggers, Code: DBL | more » |
|---|---|
DBL Logger Program version 3.0.0.17.II |
61.8 MB |
| DBV Database Viewer for database programs DBL, DBM, DBS, Code: DBV | more » |
|---|---|
DBV Database Viewer 2.3.0.1 |
22.8 MB |
Optional accessories
|
KIT - GSM/GPRS modem LP040 with accessories for Sxxxx, Rxxxx loggers
code: KIT-GSM-L
|
COM adapter with protection IP65
code: LP012
|
GSM/GPRS MODEM for data loggers of Sxxxx, Rxxxx, Gxxxx families
code: LP040
|
|
antenna for GSM modem FASTRACK
code: MP009/1
|
AC/DC adapter 230Vac to 24Vdc/1A, switch-mode
code: A1940
|
Backup power supply for GSM modem LP040
code: BP12
|
|
Communication cable for GSM modem
code: QMS2901
|
Transducer USB/RS232 complete
code: MP006
|
Self Adhesive Dual Lock
code: MD036
|
|
Wall holder for GPRS modem
code: MP036
|
DIN Rail 35mm holder for GPRS modem
code: MP037
|
One time fee for using M2M server - applied for each data logger with modem
code: SLU302
|
|
Start/stop magnet
code: LP004
|
USB adapter
code: LP003
|
COM adapter with protection IP65
code: LP012
|
|
LAN adapter with 0.5 meter cable
code: LP005
|
LAN adapter with 5 meter cable
code: LP005-5
|
Lithium battery 3,6V/AA
code: A4203
|
|
wall holder for datalogger
code: F9000
|
Self Adhesive Dual Lock
code: MD036
|
9pin female connector for signal connection, IP67 protection
code: K0921
|
|
9pin female connector for S3541,S50x1,S60x1 signal connection
code: K0925
|
Connection adapter for loggers
code: K0945
|
|
DBL Logger Program - database software for Sxxxx, Rxxxx, Gxxxx data loggers
code: DBL
Database program package. |
|
DBV Database Viewer for database programs DBL, DBM, DBS
code: DBV
Low cost browser DBV Database Viewer enables several clients to view database from different places on network/internet. |
|
Program for Data Loggers Sxxxx, Rxxxx, Gxxxx, Dxxxx
code: SWR004
Program for Windows for data loggers of Rxxxx, Sxxxx, Gxxxx, Dxxxx, ZV families. |
|
LAN adapter with 0.5 meter cable
code: LP005
LAN adapter - external converter for Sxxxx, Rxxxx loggers communication with the PC via Ethernet, including ac/dc adapter 100 to 240Vac/5Vdc.
Length of the cable 0.5 m.
Protection IP65.
Exceeding of adjusted limits is alarmed by sending e-mail message or SNMP trap. |
|
0-20mA current datalogger with display
code: S6011
Data logger is designed for record of current. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter. |
|
dual chann. 0-5V voltage datalogger with display
code: S5021
Data logger is designed for record of voltage. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter. |


COMET SYSTEM, s.r.o.
Instruction Manual
SWR004 Program for Data Loggers version 3.0.0.15
DBL Logger Program version 3.0.0.17.II