H0530 Temperature transmitter and regulator with Ethernet interface
|
|
code: H0530 Ambient temperature transmitter with two relay outputs. Built-in temperature sensor. Temperature transmitter is equipped with three two-state inputs for detection of two-state signals - e.g. power presence, water, smoke, airflow, glass break detection, door contact. Included in delivery:
|
Features
Temperature transmitter is equipped with three binary inputs for detection of two-state events - e.g. water, smoke, glass break detection, door contact.
Degrees Celsius and Fahrenheit are user selectable.
Parameters are easy adjustable from transmitter keyboard or from the computer.
Transmitter is equipped with two relay outputs for alarm indication or control of external devices. For each relay setting of delay, hysteresis, audible alarm is enabled.
Easy creation of online data acquisition system from Ethernet sensors by using new low cost database software Comet

- see also Optional Accessories.
| MODES OF COMMUNICATION | |
|---|---|
| Modbus TCP: | Modbus TCP protocol enables to read measured values, set alarm limits, adjust the probe. |
| Telnet: | Port 9999 enables to set alarm limits (lower, upper limits, hysteresis for measured values and time delay), e-mail addresses, SNMP addresses, probe description, refresh of www pages (10s to 65535s), set storing interval to history (10s to 65535s), enable each communication channel. Capacity of the history memory is 100 sets of temperature. Password protection of this port is enabled. Automatic IP address assignment from DHCP server is also enabled. |
| WWW pages: | User selectable design of www pages enabling to display curve of measurement history. User can design the look of www pages and temperature values history. |
| SNMP: | It is possible to read actual values and alarm limits. In case of alarm creation warning message (trap) is sent to addresses defined by the user (maximum three addresses). |
| SOAP: | Online transmitter enables to send actual measured data in the format of SOAP message to selected web server in preset interval 10-65535 s. |
Online transmitter enables to monitor measured values. In case of exceeding of adjusted limits warning message can be sent to specified addresses.
There are the following options of alarm indication:
| ALARM INDICATION OPTIONS | |
|---|---|
| E-mail: | In case of alarm creation warning e-mail message is sent to addresses defined by the user (maximum three addresses) or via e-mail to SMS message. Basic SMTP autentization is supported. |
| SNMP: | In case of exceeding of adjusted temperature value limits alarm is activated and warning trap is sent to user specified IP addresses (maximum 3 addresses). |
| WWW pages: | In case of exceeding of adjusted temperature value limits active alarm is displayed on www page. |
| syslog: | Online transmitter enables to send text messages to selected syslog server after different events appear. E.g. after transmitter restart, alarm activation, communication error with SNTP, after firmware change, after alarm termination, after communication error with SOAP server. |
Synchronizing of time and record to www table and measured values history is enabled by SNTP via Internet.
For acquiring values from several transmitters, also third party software is possible to use. Tested functionality is with programs:
LabVIEW from National Instruments, by means of the free Modbus Library for LabVIEW.
TIRS.NET - transmitters are also directly supported by program TIRS.NET from Coral s.r.o. company. Please download demo enabling full work with transmitters.
Tested functionality is also with program ControlWeb
Technical Data
| Technical parameters | Value |
|---|---|
| Output | Ethernet |
| Measured Value | Temperature |
| Construction Type | Ambient Air |
| Design | Industrial |
| Temperature Measuring Range | -30 to +80°C |
| Relay Output | Yes |
| Two-State Input | Yes |
| Lcd Display | Yes |
| Accuracy of temperature output | ±0.4°C |
| Resolution | 0.1°C |
| Measuring interval | 2s |
| Available temperature units | degrees Celsius, degrees Fahrenheit |
| Temperature operating range | -30 to +80°C |
| IP protection | IP40 |
| Number of relay outputs | 2 |
| Maximum switching voltage, current and power of the relay output | 50V, 2A, 60VA |
| Number of binary inputs | 3 |
| Signal for binary inputs | dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated. |
| Minimum pulse length at binary input | 500ms |
| Low voltage level at binary input | 0 to +0.5V |
| High voltage level at binary input | +3.0 to +30V |
| Audible alarm | built-in beeper - switchable |
| LAN connection | RJ-45 connector, 10Base-T or 100Base-TX |
| Communication protocols | WWW, ModbusTCP, SNMPv1, SOAP |
| Alarm protocols | E-mail (SMTP authentication is supported), SNMP Trap, Syslog |
| Configuration | T-Sensor, Telnet, keyboard |
| Temperature operating range of LCD display | readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C |
| Power | 9 to 30Vdc, maximum consumption 1W |
| Power connector | co-axial, diameter 5.5 x 2.1mm |
| Dimensions | 136 x 191 x 45mm (W x H x D), stem length 53mm |
| Weight | approximately 340g |
| Warranty | 2 years |
| size | |
|---|---|
Instruction Manual |
2.1 MB |
Quick Start Manual |
770 kB |
Datasheet |
1.5 MB |
Declaration of Conformity |
30 kB |
MIB tables |
250 kB |
| Program TSensor - free configuration program for transmitters and transducers, Code: TSensor | more » |
|---|---|
TSensor - free configuration program version 3.0.5.0 |
2.6 MB |
TSensor - revision history |
8 kB |
| Program SensorReader - free program for data read and store from one sensor, Code: SensorRead | more » |
|---|---|
SensorReader - free program for data recording from one sensor, version 2.0.1.0 |
1.3 MB |
| DBS Sensor Monitor - database program for data acquisition from Ethernet sensors P8xxx, Tx5xx, Hx5xx, Code: DBS | more » |
|---|---|
DBS Database Sensor Monitor version 2.3.0.1_II |
55.2 MB |
| DBV Database Viewer for database programs DBL, DBM, DBS, Code: DBV | more » |
|---|---|
DBV Database Viewer 2.3.0.1 |
22.8 MB |
Optional accessories
|
ac/dc adapter 230Vac to 12Vdc/0.5A
code: A1515
|
The LD-12 flood detector
code: LD12
|
The optical smoke detector SD-280
code: SD280
|
|
Motion detector JS20
code: JS20
|
Magnetic door contact SA-200-A
code: SA200A
|
Magnetic door contact with cable length 10m
code: SA200A-10
|
|
Magnetic door contact with cable length 15m
code: SA200A-15
|
Magnetic door contact with cable length 2m
code: SA200A-2
|
Magnetic door contact with cable length 20m
code: SA200A-20
|
|
Magnetic door contact with cable length 30m
code: SA200A-30
|
Magnetic door contact with cable length 5m
code: SA200A-5
|
Power detector SP008
code: SP008
|
|
Tool for easy connection to WAGO terminals 233 for serial output transmitters
code: SP006
|
KIT-GSM modem Fastrack Xtend
code: KIT-GSM-W
|
TL-POE10R - PoE splitter
code: TL-POE
|
|
TP-LINK-TL WA5110G wifi adapter
code: TP-LINK-TL
|
|
DBS Sensor Monitor - database program for data acquisition from Ethernet sensors P8xxx, Tx5xx, Hx5xx
code: DBS
Online monitoring system with sensors connected to Ethernet |
|
DBV Database Viewer for database programs DBL, DBM, DBS
code: DBV
Low cost browser DBV Database Viewer enables several clients to view database from different places on network/internet. |
|
H3060 temperature and humidity regulator with 230Vac/8A relays
code: H3060
Humidistat, thermostat with two relay outputs. Outdoor, indoor use. |
|
H4531 Temperature transmitter with alarms with Ethernet interface
code: H4531
Temperature transmitter for Pt1000 sensors with two relay outputs. |
|
H4531R temperature transmitter - rack mount monitor
code: H4531R
Temperature transmitter with two relay outputs. |
|
Web sensor T0510 - remote thermometer with Ethernet interface
code: T0510
Ambient temperature t-line Web sensor. Remote alarm. |


COMET SYSTEM, s.r.o.
Instruction Manual
MIB tables
TSensor - free configuration program version 3.0.5.0
TSensor - revision history